Contacts Products About us Home Russian version
    

Who is online?

   Locomotive meters

SET-1.01

PURPOSE AND FIELD OF APPLICATION

        The meters are intended for accounting of active and reactive electrical energy of the forward and reverse direction in single-phase power circuits of alternating current.

    The electricity meters can be used for measuring instantaneous values of active, reactive and total power, voltage, current and power factor, network frequency  and temperature inside the meter.

    The meters can be used in an electric vehicle which is propelled by an alternating current motor and operates in the traction and recuperation mode.

    The energy meters can be used either independently or as a component of:
  • automated systems for commercial energy accounting (ASKUE);
  • automated dispatch control systems (ASDU);
  • automated systems for recording alternating current flow and auto control data.

NORMATIVE AND LEGAL BACKING

    IEC 62052-11:2003

TECHNICAL FEATURES

  • Digital signal processing.
  • Four pulse outputs.
  • Communication interfaces: RS-485, optoport, CAN, fiber-optic communication line.
  • Current transformer connection and voltage transformer or direct voltage connection are possible.
  • Nonvolatile memory.

FUNCTIONAL CAPABILITIES

    The electricity meters provide the possibility to programme from an external PC through RS-485 interface or optoport the following parameters:

  • network address;
  • data access password of the first and the second level;
  • exchange rate through RS-485 interface (only through RS-485 interface);
  • exchange rate through CAN interface and  period for the data output in CAN;
  • the locomotive’s number and section number (name of the accounting point);
  • current transformation ratio;
  • period for the data output on the display;
  • programmable flags.

    The electricity meters provide the possibility to control from an external PC through RS-485 interface or optoport:

  • display modes;
  • reset of stored energy registers;
  • the meter restart.

    The electricity meters provide the possibility to read with the help of an external PC through RS-485 interface or optoport the following parameters and data:

  • serial number and date of production;
  • network address;
  • the locomotive’s number and section number (name of the accounting point);
  • current transformation ratio;
  • measured active and reactive energy of the forward and reverse direction;
  • current values of active and reactive energy of the forward and reverse direction;
  • instantaneous values of active, reactive and total power;
  • voltage, current and power factor;
  • network frequency;
  • temperature inside the meter;
  • version of the meter’s software;
  • meter status words;
  • programmable flags;
  • modification;
  • display mode and period for the data output on the display;
  • exchange rate through CAN interface and period for the data output in CAN.

    SET-1.01.04 and SET-1.01.05 energy meters ensure transmission of measurement data packets through CAN interface with programmable transmission period.

    SET-1.01.02 and SET-1.01.03 energy meters provide periodic one-way data packet transmission through fiber-optic communication line.

TECHNICAL DATA

Quantity

Value

Nominal (maximum) current,

5 (7,5)

Sensitivity current, m

5

Nominal supply and measuring voltage (Unom), V

230

Range of:
    measuring voltage
    supply voltage


from 0,7 t 1,2 Unom (from 161 t 276 V alternating voltage);
from 0,4 t 1,2 Unom (from 92 t 276 V alternating or constant voltage)

Power-line frequency and frequency of measuring network

from 47,5 t 52,5 Hz

Accuracy class when measuring:
    active energy and power
    reactive energy and power


0,5 S
1,0

Maximum permissible main error when measuring:

    voltage
1u = ± 0,9 % in the range from  0,7 t 1,2 Unom
    current
3, %
    frequency
2f= ± 0,1 %

Power consumption in voltage supply circuit and in voltage measuring circuit

active < 2 W, total < 4 V·
(U =230 V, F =50 Hz)

Power consumption in current circuit

< 0,3 ( I =5 , F =50 Hz)

Input resistance of the voltage measuring circuit

1 mOhm (separate power supply)

Number of indicated decimal  liquid-crystal display digits

8

Data safety when switching off the power supply

10 years (the meter is off) at temperature 50°

Data protection

Two access levels and memory hardware protection of metrological factors

Rate of data exchange:
    via RS -485 interface
    through optoport
    via CAN interface
    through fiber-optic communication line


9600, 4800, 2400, 1200 bit/sec
9600 bit/sec
250000 bit/sec
9600 bit/sec

Working and service conditions:
    ambient air temperature, °
    relative humidity, %
    pressure, kPa (mm of mercury)


from - 40 to +60;
up to 100% at 25 °;
from 70 t 106,7 (from 537 t 800);

Recalibration interval, years

10

Self-diagnostics

Iterative, incessant

Average error-free running time

90000 h

Average service life

30 years

Mass

not more than 1,5 kg

Measurements

170x325x77 mm

 

New products

Time-schedule of workshops

Copyright

Copyright © 2012
Nizhny Novgorod Factory named after M.V. Frunze.
All rights reserved.
 
Up