Contacts Products About us Home Russian version
    

Who is online?

   Models which are not more series-produced

SEO-1.12

PURPOSE AND FIELD OF APPLICATION

    The meters are intended for metering of active electrical energy in two-wire power circuits of alternating current with the frequency of 50Hz.

    The data on power consumption is indicated on the liquid-crystal display or on the electrical and mechanical reading device which is protected from electromagnetic influences. Due to telemetric data output of the meters they can be used as a component of any automated systems for commercial energy accounting.

NORMATIVE AND LEGAL BACKING

    IEC 62052-11:2003

TECHNICAL FEATURES

  • The electrical and mechanical reading device or the liquid-crystal display indicates the amount of the consumed power in kilowatt-hour with the accuracy of one hundredth of a unit.
  • LED indication of the current in the load circuit: the more the load, the more often the LED blinks.
  • Reading devices with the reverse motion lock and protection from electromagnetic influences are used in the electricity meters.
  • The electricity meters are provided with a pulse output, which is galvanically separated from the network and ensures transmission of information on the quantity of active energy to a remote data collection system through a two-wire communication line.

TECHNICAL DATA

Quantity

Value

Nominal voltage (Unom), V

230

Nominal (maximum) current,

5 (50)

Accuracy class

1,0 or 2,0

Working range of network frequency, Hz

from 47,5 to 52,5

Sensitivity, :
    for energy meters of the accuracy class 1
    for energy meters of the accuracy class 2

0,0125
0,025

Transmission ratio, pulses./kwh

6400 or 4000

Total power, consumed by the meter’s serial circuit at the rated current V*A

0,1

Power, consumed by the meter’s voltage circuit at the nominal voltage:
    total, V·
    active, W

7
1

Fixed maximum working temperature range, °

from -20 to +55
from -40 to +55

Recalibration interval, years

16

Average service life till overhaul, years

30

Measuremants of the meter, mm

17914065

Mass, kg

not more than 0,65

MODIFICATIONS

 

New products

Time-schedule of workshops

Copyright

Copyright © 2012
Nizhny Novgorod Factory named after M.V. Frunze.
All rights reserved.
 
Up