Contacts Products About us Home Russian version
    

Who is online?

   Electricity Meters    Three-phase meters  Multifunction meters

PSCH-4TM.05MD

Nominal voltage - 3x(57,7-115)/(100-200) or 3x(120-230)/(208-400) V
Nominal (maximum) current - 1(2) or 5(10), 5(80)
Accuracy class - 0,5S or 1,0 (1,0 or 2,0)
Number of tariffs - 4



   Electricity Meters    Three-phase meters  Multifunction meters

PSCH-4TM.05MN

Nominal voltage - 3x(57,7-115)/(100-200) or 3x(120-230)/(208-400) V
Nominal (maximum) current - 1(2) or 5(10), 5(80)
Accuracy class - 0,5S or 1,0 (1,0 or 2,0)
Number of tariffs - 4



   Electricity Meters   Three-phase meters  Multifunction meters

PSCH-3.05, PSCH-3.05D

Nominal voltage – 3*(120-230)/(208-400) V
Nominal (maximum) current – 5(100)
Accuracy class when measuring active (reactive) energy – 1,0 (2,0)
Number of tariffs - 4
Communication interfaces – independent RS-485 and optoport which are of equal priority.
ModBus-similar, SET-4.02 compatible exchange protocol with the extended addressing possibility.
PSCH-3.05D modification is to be fixed on DIN-bar.

   Electricity Meters Three-phase meters Multifunction meters

PSCH-4.05D

Nominal voltage 3*(57,7-115)/(100-200) or 3*(120-230)/(208-400) V
Nominal (maximum) current 1 (1,5) or 5 (7,5)
Accuracy class when measuring active (reactive) energy - 0,5S (1,0)
Number of tariffs - 4
Communication interfaces independent and of equal priority: RS-485 and optoport
ModBus-similar, SET-4.02-compatible exchange protocol with the extended addressing possibility.
Electric power meter is designed for installation onto DIN-rail (type 35 in compliance with GOST R MEC 60715-2003).

   Electricity Meters   Three-phase meters  Multifunction meters

PSCH-4.05

Nominal voltage –3*(57,7-115)/(100-200) or 3*(120-230)/(208-400) V
Nominal (maximum) current – 1 (1,5) or 5 (7,5)
Accuracy class when measuring active (reactive) energy - 0,5S (1,0)
Number of tariffs - 4
Communication interfaces – independent and of equal priority: RS-485 and optoport
ModBus-similar, SET-4.02-compatible exchange protocol with the extended addressing possibility.

   Electricity Meters   Three-phase meters  Multifunction meters

PSCH-4.05K

Rated voltage 3(57.7-115)/(100-200) or 3(120-230)/(208-400)
Rated (maximum) current intensity 1(2) or 5(10) 5(100) A
Accuracy class when measuring active (reactive) energy 0.5S or 1.0; 1.0 or 2.0
Number of tariffs - 4
Communication interfaces independent, equally prioritized: RS-485 and optical port
ModBus-similar, SET-4TM.02-compatible exchange protocol with the option of extended addressing
Plug-in modules: GSM-communicator, PLC modems, Ethernet or ISM

   Electricity Meters   Three-phase meters  Multifunction meters

SET-4.03, SET-4.02.2

Nominal voltage – 3*(57,7-115)/(100-200) or 3*(120-230)/(208-400) V
Nominal (maximum) current – 1 (2) or 5 (10)
Accuracy class when measuring active (reactive) energy – 0,2 S or 0,5S (0,5 or 1,0)
Number of tariffs - 8
Communication interfaces – independent and of equal priority: two RS-485 and optoport (SET-4.03); RS-485 and optoport (SET-4.02)
ModBus-similar, SET-4.02 compatible exchange protocol with the extended addressing possibility.





 
 

New products

Time-schedule of workshops

Copyright

Copyright © 2012
Nizhny Novgorod Factory named after M.V. Frunze.
All rights reserved.
 
Up
Search Contacts Products About us Home