Contacts Products About us Home Russian version
    

Who is online?

   Multitariff meters

MAYAK 103ARTN

PURPOSE

Energy meters are designed for accounting of active and reactive energy of the forward and reverse direction in AC single-phase networks with the rated frequency of 50 Hz.
Energy meters may be used both in standalone mode and as part of automated measuring and information systems for electric power fiscal accounting (AMIS EPFA).

TECHNICAL FEATURES

  • Non-volatile RAM.
  • Rate card structure - 8 rates, 8 day types, rate plan:
    • - for 8 day types and 12 months (a separate one for each weekday of a month with due account for holidays);
    • - flat rate for the whole of the year per 8 day types;
    • - flat rate for the whole of the year per single day.
  • Capability to set up to 32 exceptional days.
  • Backlit liquid crystal display (LCD).
  • Communication interfaces - optical port, RS-485, PLC, RF 2400 MHz, GSM.
  • Programmable pulse output.
  • Load control function (relay or signal).
  • Enhanced security (two access levels common and individual passwords; capability to record date and time of the last energy meter disconnection from the power network, last energy meter switching on).
  • Design variant with the split architecture consists of two blocks:
    • energy meter block in outdoor mounted housing with the IP55 ingress protection rating;
    • remote terminal in casing intended for DIN-rail mounting.
  • Communication between energy meter and remote terminal is effected via a 868 MHz radio interface.

FUNCTIONAL CAPABILITIES

Non-volatile RAM of energy meters provides for recording, storing and read-out of the following values off the digital interfaces:

  • running total of active and reactive energy measured according to rates available from the date of manufacture;
  • active energy measured at the beginning of each month according to rates available over a three-year period;
  • active energy measured for each half-hour over a 125-day period;
  • active and reactive energy measured at the beginning of each day over a 125-day period;
  • power switch on / switch off time;
  • time of channel opening and closing for writing;
  • date and time prior to and upon the adjustment;
  • date and time of terminal box cover and energy meter housing cover opening and resealing.

Energy meters provide the capability to write time of day rates, current time, weekday, date, month, year, energy and power limits, consumer category.
Energy meters ensure cyclic representation of the following parameters:

  • current value of energy according to rates available;
  • total value of accumulated energy according to rates available;
  • date and time;
  • current active, reactive and full power (for reference only);
  • preset power limit;
  • value of energy since the start of the current half-hour;
  • value of monthly energy consumption per year according to each rate available;
  • effective rate;
  • rate card.

SPECIFICATIONS

Parameter designation

Value

Accuracy rating for measuring of:
   active energy
   reactive energy

1
1

Rated voltage, V

230

Preset operating voltage range, V

198 to 253

Extended operating voltage range, V

160 to 265

Maximum operating voltage range, V

0 to 265

Base (maximum current), A

5 (100)

Rated frequency, Hz

50

Starting current (sensitivity) at the time of energy measurement, A, max.

0.02

Pulse rate, imp/(kWh):
   in basic mode (A)
   in calibration mode (B)


500
10000

Active (full) power consumption by the parallel voltage circuit, W (VA), max.

1 (5)

Full power consumption by the series circuit, VA, max.

0.1

Bit rate, bit/s:
   for optical port
   for PLC
   for radio interface


9600
2400
9600

Preset operating temperature range, ˚C

-40 to +60

Number of rates

8

Internal timer accuracy, higher than, s/day

0.4

No-power data retention time, years

10

Mean time between failures, hours, min.

220000

Mean lifetime of the energy meter, years, min.

30

Weight of outdoor mounted energy meters, kg, max.

0.85

Overall dimensions of the unit, mm, max.:
   terminal of
   outdoor mounted energy meters
   outdoor mounted energy meters with the channel bracket


108 x 110 x 65
239 x 182.5 x 78
350 x 182.5 x 98

ENERGY METER DESIGN VARIANTS

Designation

Interface type

Load control

Type of antenna

Current, A
base (Ib), maximum (Imax)

MAYAK 103ARTN.131SH.2IOR2B

Optical port, radio channel
(PIM_ISM 2400.3)

signal

Integrated into PIM

5 (100)

MAYAK 103ARTN.131SH.2IOR1B

Optical port, radio channel
(PIM_ISM 2400.3)

relay

Integrated into PIM

5 (100)

MAYAK 103ARTN.131SH.2IOZH2B

Optical port, radio channel
GSM 3G + Java

signal

Integrated into the energy meter

5 (100)

MAYAK 103ARTN.131SH.2IOZH1B

Optical port, radio channel
GSM 3G + Java

relay

Integrated into the energy meter

5 (100)

MAYAK 103ARTN.131SH.2IOS2B

Optical port
PLC-modem (power mains)

signal

 

5 (100)

MAYAK 103ARTN.131SH.2IOS1B

Optical port
PLC-modem (power mains)

relay

 

5 (100)

MAYAK 103ARTN.131SH.2IOR2B

Optical port, radio channel
RF ISM-2400.?
(PIM_ISM 2400.2)

signal

Integrated into the energy meter

5 (100)

MAYAK 103ARTN.131SH.2IOR1B

Optical port, radio channel
(PIM_ISM 2400.2)

relay

Integrated into the energy meter

5 (100)

MAYAK 103ARTN.131SH.2IOR2B

Optical port, radio channel
(Zigbee TPP-01)

signal

Integrated into "ComMod Z"

5 (100)

MAYAK 103ARTN.131SH.2IOR2B

Optical port, radio channel
(Zigbee TPP-02)

signal

Integrated into the energy meter

5 (100)

MAYAK 103ARTN.131SH.2IOR1B

Optical port, radio channel
(Zigbee TPP-01)

relay

Integrated into "ComMod Z"

5 (100)

MAYAK 103ARTN.131SH.2IOR1B

Optical port, radio channel
(Zigbee TPP-02)

relay

Integrated into the energy meter

5 (100)

MAYAK 103ARTN.131SH.2IOZH2B

Optical port, radio channel
GSM TPP

signal

Integrated into the energy meter

5 (100)

MAYAK 103ARTN.131SH.2IOZH1B

Optical port, GSM

relay

Integrated into the energy meter

5 (100)

MAYAK 103ARTN.131SH.2IOZH2B

Optical port, GSM

signal

Integrated into the energy meter

5 (100)

MAYAK 103ARTN.131SH.2IOZH1B

Optical port, GSM

relay

Integrated into the energy meter

5 (100)

 

New products

Time-schedule of workshops

Copyright

Copyright © 2012
Nizhny Novgorod Factory named after M.V. Frunze.
All rights reserved.
 
Up