Multitariff meters SEB-2A.07D PURPOSE AND FIELD OF APPLICATION The meter is designed for multitariff accounting of active energy in two-wire power circuits of a.c. with the frequency of 50Hz which is differentiated in light conditions, power level and energy consumption level. The meters have a telemetric interface and a digital communication interface (optical port or RS-485) what makes it possible to use them as a component of any automated information-measuring systems for commercial energy accounting (AIISKUE). NORMATIVE AND LEGAL BACKING IEC 62052-11:2003 TECHNICAL FEATURES - Internal four-tariff tasksetter (for 12 seasons).
- 9 tariff zones per day.
- Nonvolatile memory.
- Communication interface - RS-485 or optical port.
- Programmable pulse output (power control mode and output automaton shutdown mode. Inspection, calibration testing, telemetry).
- Indication type - liquid-crystal display or mechanical reading device.
- A shunt is used as a current sensor.
- Possibility to connect an external alternate power source (9-12 V) to read indication of the liquid-crystal display in the absence of 230V.
- Electronic seals of interface and terminal blocks.
- The meters are to be fixed on DIN-bar.
FUNCTIONAL CAPABILITIES The electricity meters ensure registration and storage of the data: - registration and storage of the data on the consumed electrical energy as per tariff zones;
- registration and storage of the data on the electrical energy measured as at the beginning of the month as per tariff zones in the course of 24 months;
- registration and storage of the data on the consumed electrical energy as per tariff zones with exceeding the fixed power limit;
- permission/prohibition for automatic changing-over to ‘summer’ or ‘winter’ time;
- registration of the time when protective terminal covers of the interface were opened/closed and storage of 32 events;
- registration of the time before and after diurnal time correction and storage of 32 events;
- registration of the time data when the meter was energized and de-energized and storage of 32 events;
- registration of the time when recording channel was opened/closed and storage of 32 events;
- registration and storage of the data on the measured electrical energy and maximum power of each half-hour in the course of two months.
The electricity meters have the possibility to reprogramme through RS-485 interface or optical port the following parameters: - data rate;
- multipart password, individual password and address.
The electricity meters have the possibility to read and reprogramme through RS-485 interface or optical port the following parameters: - category of a consumer;
- holiday schedule;
- annual tariff schedule (for every day of the week and holiday of the month);
- power limit and monthly energy limit;
- permission and prohibition for automatic changing-over to ‘summer’ or ‘winter’ time;
- current time and date;
- function of changing the pulse output: to the meter calibration mode or to energy control regime with the possibility to form a tripping signal;
- indication mode and indication time in the range from 6 to 60 sec (of the meter with liquid-crystal display);
- permission for one-tariff operating mode of the meter.
TECHNICAL DATA Quantity | Value | Recalibration interval, years | 16 | Accuracy class | 1 | Nominal voltage, V | 230 | Fixed working voltage range, V | 198-253 | Extended working voltage range, V | 160-265 | Utmost working voltage range, V | 0-265 | Base/ maximum current, À | 5/50 or 10/100 | Rated frequency, Hz | 50 | Starter current (sensitivity), À, not more than: for base current 5À for base current 10 À | 0,02 0,04 | Accuracy movement of internal timer clock, sec/day | 0,5 | Change of accuracy movement under influence of temperature, not more than, sec/°Ñ/day: at temperature from -10 up to +45 °Ñ at temperature from -40 up to -10 °Ñ at temperature from +45 up to +60 °Ñ | 0,15 0,5 0,5 | Transmission ratio of the meter’s pulse output in the main (calibration) mode, pulses/kwh: for base current 5À for base current 10 À | 500 (10000) 250 (5000) | Power demand, V·À (W), not more than: in voltage circuit in current circuit | 5 (1,5) 0,1
| Number of tariffs | up to 4 | Reserve supply voltage, V | from 9 to 12 | Fixed working temperature range, °Ñ | from -40 to +60 | Average error-free running time, h | not less than 140000 | Average service life of the meter, years | not less than 30 | Information storing time when switching off the power supply, years | 10 | Mass, kg | not more than 0,45 | Measurements (length; width; height), mm | 108õ110õ65 | MODIFICATIONS |
|
|