Electricity Meters  Three-phase meters  Unitariff meters PSCH-3ÀR.05.2Ì Nominal voltage – 3õ(120-230)/(208-400) V Nominal (maximum) current - 5 (60) èëè 5 (100) À Accuracy class when measuring active (reactive) energy - 1,0 (1,0) Number of tariffs - 1 Two telemetric outputs Communication interface - optical interface (PSCH-3ÀR.05Ì.121) |
|
Electricity Meters  Three-phase meters  Unitariff meters PSCH-4À.05.2Ì Nominal voltage – 3õ57,7/100, 3õ(120-230)/(208-400) V Nominal (maximum) current - 5 (7,5) À Accuracy class - 0,5S Number of tariffs - 1 One or two telemetric outputs |
|
Electricity Meters  Three-phase meters  Unitariff meters PSCH-4ÀR.05.2M Nominal voltage – 3õ57,7/100, 3õ(120-230)/(208-400) V Nominal (maximum) current - 5 (7,5) À Accuracy class when measuring active (reactive) energy - 0,5S (1,0) Number of tariffs - 1 Two telemetric outputs Communication interface - optical interface (PSCH-4ÀR.05Ì.122) |
|
Electricity Meters  Three-phase meters  Unitariff meters PSCH-3A.06
Rated voltage – 3õ57.7; 3õ230/400V
Rated (maximum) current – 5 (10), 5 (60) or 5 (100) A
Accuracy class - 1 or 0.5 S
Number of tariffs – 1
|
|
Electricity Meters  Three-phase meters  Unitariff meters PSCH-3AR.06
Rated voltage – 3õ57,7/100, 3õ230/400 V
Rated (maximum) current – 5 (10), 5 (60) or 5 (100) A
Accuracy class - 1(2) or 0,5S(1)
Number of tariffs – 1
|
|
Electricity Meters  Three-phase meters  Unitariff meters PSCH-3À.07D
Rated voltage - 3õ230/400 or 3õ57.7/100 V
Rated (maximum) current - 5(7.5), 5 (60), 10 (100) À
Accuracy class when measuring active energy – 1.0 or 0.5S
Number of tariffs- 1
Communication interface – optoport
Electric power meter is designed for installation onto DIN-rail (type ÒÍ35 in compliance with GOST R MEC 60715-2003).
|
|
Electricity Meters  Three-phase meters  Unitariff meters PSCH-3ÀR.07D
Rated voltage - 3õ(120-230)/(208-400) or 3õ57.7/100 V
Rated (maximum) current - 5(7.5), 5 (60), 10 (100) À
Accuracy class when measuring active v(reactive) energy– 1.0 or 0.5S (1.0 or 2.0)
Number of tariffs - 1
Communication interface – RS-485, optoport
Electric power meter is designed for installation onto DIN-rail (type ÒÍ35 in compliance with GOST R MEC 60715-2003).
|
|
Electricity Meters  Three-phase meters  Multitariff meters PSCH-3A.06T
Rated voltage – 3õ57.7; 3õ(120-230)/(208-400)V
Rated (maximum) current – 5 (7.5); 5 (50); 10 (100) A
Accuracy class - 1 or 0.5 S
Number of tariffs – 4
Communication interface – RS-485 or optical port
|
|
Electricity Meters  Three-phase meters  Multitariff meters PSCH-3ÒÀ.07 Nominal voltage – 3*230/400 V or 3*(120-230)/(208-400) Nominal (maximum) current – 5 (7,5); 5 (50); 10 (100) À Accuracy class - 1,0 Number of tariffs – 2 or 4 Communication interfaces – RS-485 or optoport |
|
Electricity Meters  Three-phase meters  Multitariff meters PSCH-3TA.08
Rated voltage – 3õ(120-230)/(208-400)
Rated (maximum) current – 5(60) or 5(100)
Accuracy class – 1
Number of tariffs – 4
Communication interfaces – RS-485
|
|
Electricity Meters  Three-phase meters  Multitariff meters PSCH-3TA.09 (COMMUNICATOR)
Rated voltage – 3õ(120-230)/(208-400)
Rated (maximum) current – 5(60) or 5(100)
Accuracy class – 1
Number of tariffs – 4
Communication interfaces – RS-485
|
|
Electricity Meters  Three-phase meters  Multitariff meters PSCH-3ART.07, PSCH-3ART.07D Nominal voltage – 3*(120-230)/(208-400) Nominal (maximum) current – 5 (7,5); 5 (50); 10 (100) À) Accuracy class when measuring active (reactive) energy - 0,5S (1,0) or 1,0 (2,0) Number of tariffs – 4 Communication interfaces – RS-485 or optoport PSCH-3ART.07D is to be fixed on DIN-bar. |
|
Electricity Meters  Three-phase meters  Multitariff meters PSCH-3ART.08 Rated voltage – 3õ57.7/100; 3õ(120-230)/(208-400)
Rated (maximum) current intensity – 5 (7.5); 5 (50) or 10 (100)
Accuracy class for measuring of active (reactive) energy - Î,5 S or 1 for A; 2 for R
Number of tariffs – 4
Communication interface – RS-485 and optical port
|
|
Electricity Meters  Three-phase meters  Multitariff meters PSCH-3ART.09 Rated voltage – 3õ57.7; 3õ(120-230)/(208-400)V
Rated (maximum) current – 5 (7.5); 5 (60); or 10 (100) A
Accuracy class for measuring of active (reactive) energy – 0.5 S or 1 (2)
Number of tariffs – 4
Communication interface – RS-485 and optical port
|
|
Electricity Meters  Three-phase meters  Multifunction meters PSCH-3ÒÌ.05Ì, PSCH-3ÒÌ.05D Nominal voltage – 3*(120-230)/(208-400) V Nominal (maximum) current – 5(100) À Accuracy class when measuring active (reactive) energy – 1,0 (2,0) Number of tariffs - 4 Communication interfaces – independent RS-485 and optoport which are of equal priority. ModBus-similar, SET-4ÒÌ.02 compatible exchange protocol with the extended addressing possibility. PSCH-3ÒÌ.05D modification is to be fixed on DIN-bar. |
|
Electricity Meters  Three-phase meters  Multifunction meters PSCH-4ÒÌ.05D
Nominal voltage –3*(57,7-115)/(100-200) or 3*(120-230)/(208-400) V
Nominal (maximum) current – 1 (1,5) or 5 (7,5) À
Accuracy class when measuring active (reactive) energy - 0,5S (1,0)
Number of tariffs - 4
Communication interfaces – independent and of equal priority: RS-485 and optoport
ModBus-similar, SET-4ÒÌ.02-compatible exchange protocol with the extended addressing possibility.
Electric power meter is designed for installation onto DIN-rail (type ÒÍ35 in compliance with GOST R MEC 60715-2003).
|
|
Electricity Meters  Three-phase meters  Multifunction meters PSCH-4ÒÌ.05Ì Nominal voltage –3*(57,7-115)/(100-200) or 3*(120-230)/(208-400) V Nominal (maximum) current – 1 (1,5) or 5 (7,5) À Accuracy class when measuring active (reactive) energy - 0,5S (1,0) Number of tariffs - 4 Communication interfaces – independent and of equal priority: RS-485 and optoport ModBus-similar, SET-4ÒÌ.02-compatible exchange protocol with the extended addressing possibility. |
|
Electricity Meters  Three-phase meters  Multifunction meters PSCH-4ÒÌ.05ÌK Rated voltage – 3õ(57.7-115)/(100-200) or 3õ(120-230)/(208-400)
Rated (maximum) current intensity – 1(2) or 5(10) 5(100) A
Accuracy class when measuring active (reactive) energy – 0.5S or 1.0; 1.0 or 2.0
Number of tariffs - 4
Communication interfaces – independent, equally prioritized: RS-485 and optical port
ModBus-similar, SET-4TM.02-compatible exchange protocol with the option of extended addressing
Plug-in modules: GSM-communicator, PLC modems, Ethernet or ISM
|
|
Electricity Meters  Three-phase meters  Multifunction meters SET-4ÒÌ.03Ì, SET-4ÒÌ.02.2Ì Nominal voltage – 3*(57,7-115)/(100-200) or 3*(120-230)/(208-400) V Nominal (maximum) current – 1 (2) or 5 (10) À Accuracy class when measuring active (reactive) energy – 0,2 S or 0,5S (0,5 or 1,0) Number of tariffs - 8 Communication interfaces – independent and of equal priority: two RS-485 and optoport (SET-4ÒÌ.03Ì); RS-485 and optoport (SET-4ÒÌ.02Ì) ModBus-similar, SET-4ÒÌ.02 compatible exchange protocol with the extended addressing possibility.
|
|